Use the procedures below to create or edit settings on ICP units, including reports, battery and power, and interruption. Refer to the list of Related Topics for more information on setting up unit information, alerts, location, journal, and templates.
For an overview and field descriptions, see ICP: Unit Settings Overview.
To display the navigation pane or Settings tabs in Unit Admin:
- Click All Units in Unit System Status.
- Select a unit in the Unit column of All Units View to display Unit Detail.
- Click Settings or the pencil icon to display Unit Admin.
- The Settings tab displays. Click tab to access unit settings.
Perform any of the following tasks for an ICP unit in the Time and Reports tab in the Settings tab on Unit Admin:
Perform any of the following tasks for an ICP unit in the Measurement Settings tab in the Settings tab on Unit Admin:
Perform any of the following tasks for an ICP unit in the Power and AC tab in the Settings tab on Unit Admin:
Perform any of the following tasks for an ICP unit in the Interruption tab in the Settings tab on Unit Admin:
To set report interval time ˆtop of pageˆ
- Type the number of hours in the Report Interval (hours) field.
- Or, type a zero (0) in the Report Interval (hours) field for day of the month reports.
- Click Save to save settings.
To set how often a health check status is sent ˆtop of pageˆ
- Type a number (in hours) in the Health Check Frequency (Hours) field.
- Or, type a zero (0) in the Health Check Frequency (Hours) field to disable reports.
- Click Save to save settings.
To show or hide Isolation Device settings ˆtop of pageˆ
- To show settings, click the Show advanced settings check box to add a check to the box. Settings under Isolation Device display.
- To hide settings, click the Show advanced settings check box to remove the check from the box. Settings under Isolation Device do not display.
- Click Save to save settings.
To set the time between analog checks ˆtop of pageˆ
- Type the number of minutes in the Check Interval (minutes) field.
- Click Save to save settings.
To set the number of double checks for alarm verification ˆtop of pageˆ
- Type the number double checks (at least 2) in the Number of double checks field.
- Click Save to save settings.
To set the amount of time between double checks ˆtop of pageˆ
- Type the number of minutes, up to 65535, in the Double check frequency (min) field.
- Click Save to save settings.
To set amount of time for digital channel persistence ˆtop of pageˆ
- Type the number of minutes, 0-255, in the Digital Persistence (min) field.
- Click Save to save settings.
To set the amount of time the isolation device will be closed ˆtop of pageˆ
- Type a number, up to 127, in the Isolation device closed after each measurement field.
- Click Save to save settings.
To set the channel used to monitor whether isolation device is closed ˆtop of pageˆ
- Select a channel from the list of options in the Isolation device confirm channel field.
- If a channel is not used for the isolation device, select Not Used from the list of options.
- Click Save to save settings.
To set the channel used to control the isolation device ˆtop of pageˆ
- Select a channel from the list of options in the Isolation device control field.
- If a channel is not used for the isolation device, select Not Used from the list of options.
- Click Save to save settings.
To set the channel used to confirm the isolation device is open ˆtop of pageˆ
- Select a channel from the list of options in the Isolation open confirm field.
- If a channel is not used for the isolation device, select Not Used from the list of options.
- Click Save to save settings.
To set the time before isolation device close is unsuccessful ˆtop of pageˆ
- Type the number of seconds, from 0 - 255, in the Isolation device timeout (s) field.
- Click Save to save settings.
To show or hide Power Saving Options ˆtop of pageˆ
- To show settings, click the Advanced options check box to add a check to the box. Settings under Power Savings Options display.
- To hide settings, click the Show advanced settings check box to remove the check from the box. Settings under Power Savings Options do not display.
- Click Save to save settings.
To set percentage of charging failure ˆtop of pageˆ
- Type the percentage (from 1- 99) of previous battery voltage during charging that is considered a charging failure in the Charge percentage failure field.
- Click Save to save settings.
To enable or disable the alarm for the Charge percentage failure setting ˆtop of pageˆ
- To enable the alarm, click the Alarm enabled on RMU check box to add a check to the box.
- To disable the alarm, click the Alarm enabled on RMU check box to remove the check mark from the box.
- Click Save to save settings.
To set the high voltage level at which the battery will alarm ˆtop of pageˆ
- Type a voltage in the Battery High Voltage field.
- Click Save to save settings.
To set the low voltage level at which the battery will alarm ˆtop of pageˆ
- Type a voltage in the Low battery voltage field.
- Click Save to save settings.
To set the time for AC present persistence ˆtop of pageˆ
- Type a number (in minutes) in the AC present persistence (min) field.
- Click Save to save settings.
To select the analog channel used for outage detection ˆtop of pageˆ
- Select the analog channel from the list of options in the Analog channel used for outage detection field.
- To denote that no analog channel is used, select Not Used from the list of options.
- Click Save to save settings.
To select the digital channel used for outage detection ˆtop of pageˆ
- Select the digital channel from the list of options in the Digital channel used field.
- To denote that no digital channel is used, select Not Used from the list of options.
- Click Save to save settings.
To set the time for battery check interval for low battery ˆtop of pageˆ
- Type a number (in seconds) from 60 - 65000 in the Battery check interval when battery low field.
- Click Save to save settings.
To set loop time for third party software ˆtop of pageˆ
- Type the number of seconds in the Loop time field.
- Click Save to save settings.
To set the time of day to resume operation ˆtop of pageˆ
- Type the hour, from 0 - 24, in the Resume Hour field.
- Click Save to save settings.
To set the time of day to suspend operation ˆtop of pageˆ
- Type the hour, from 0 - 24, in the Suspend Hour field.
- Click Save to save settings.
To set whether an interrupter is installed ˆtop of pageˆ
- To denote that an interrupter is installed, click the Interrupter Installed check box to add a check to the box.
- To denote that an interrupter is not installed, click the Interrupter Installed check box to remove the check from the box.
- Click Save to save settings.
To enable/disable posting analog values when interrupting ˆtop of pageˆ
- To enable posting, click the Post Analog Values when Interrupting check box to add a check mark to the check box.
- To disable posting, click the Post Analog Values when Interrupting check box to remove the check mark from the check box.
- Click Save to save settings or Reset to cancel changes and return to the last, saved setting.
To add program information ˆtop of pageˆ
- Type information about Program 1 in the Program 1 field.
- Repeat for Programs 2-4.
- Click Save to save settings.
To add interrupter's serial number ˆtop of pageˆ
- Type the interrupter's serial number in the Serial Number field.
- Click Save to save settings.
To add the interrupter's software version number ˆtop of pageˆ
- Type the interrupter's software version number in the Interruption version field.
- Click Save to save settings.
To set the analog channel used to verify interruption ˆtop of pageˆ
- Select the channel from the list of options in the Analog channel field.
- Click Save to save settings.
To select interruption power ˆtop of pageˆ
- Select an option from the list of options in the Interruption powered field.
- Click Save to save settings.
This setting should be done by a support specialist
To set day of the month for instant off schedule ˆtop of pageˆ
- Select a schedule from the list of options in the Instant Off Schedule field.
- Click Save to save settings.
To set time of day for instant off schedule ˆtop of pageˆ
- Select a time from the list of options in the Instant off start time field.
- Click Save to save settings.
To set delay between instant off and measurement ˆtop of pageˆ
- Type a number (in milliseconds) from 10 - 2200 in the Delay (ms) field.
- Click Save to save settings.
To select interruption program ˆtop of pageˆ
- Type a program number in the Interruption program field.
- Click Save to save settings.
To enable or disable instant off for channels 1-4 ˆtop of pageˆ
- Click the Analog 1 check box to add a check mark to the box and enable channel 1.
- Click the Analog 2 check box to add a check mark to the box and enable channel 2.
- Click the Analog 3 check box to add a check mark to the box and enable channel 3.
- Click the Analog 4 check box to add a check mark to the box and enable channel 4.
- Click the Analog 5 check box to add a check mark to the box and enable channel 5.
- To disable any channel, click the check box to remove the check mark from the box.
- Click Save to save settings.
To enable or disable interruption failure notification ˆtop of pageˆ
- To enable alarm, click the Mask Interruption Alarms (on unit) check box to add a check mark to the box.
- To disable alarm, click the check box again to remove the check mark from the box.